Technical Data - Hilti TE 6-S Manual De Instrucciones

Ocultar thumbs Ver también para TE 6-S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68

4. Technical data

Tool
Nominal power input
Nominal voltage
Nominal current
Mains frequency
en
Weight as per EPTA-Procedure 01/2003
Dimensions (l×w×h)
Speed
Hammering speed (full hammering action)
Hammering speed (reduced hammering action)
Single impact energy (full hammering action)
Single impact energy (reduced hammering action)
Drilling dia. range in concrete/masonry
(hammer drill bits)
Drilling dia. range in wood (wood drill bits)
Drilling dia. range in wood (hole saws)
Drilling dia. range in metal (solid metal)
Drilling dia. range in metal (sheet metal,
max. 2 mm thick)
Drilling dia. range with thin-walled diamond core bits
(reduced hammering action)
Drilling performance in medium-hard concrete
Double insulated (as per EN 60 745)
Mechanical slip clutch
Vibration-absorbing grip and side handle
Interference immunity
Radio and television interference suppression
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised
test given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary asses-
sment of exposure. The declared vibration emission level represents the main applications of the tool. However if
the tool is used for different applications, with different accessories or poorly maintained, the vibration emission
may differ. This may significantly increase the exposure level over the total working period. An estimation of the
level of exposure to vibration should also take into account the times when the tool is switched off or when it is
running but not actually doing the job. This may significantly reduce the exposure level over the total working peri-
od. Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the
tool and the accessories, keep the hands warm, organisation of work patterns.
Noise and vibration information (according to EN 60745)
Typical A-weighted sound power level
Typical A-weighted emission sound pressure level
For the given sound power level as per EN 60745, the tolerance is 3 dB.
Wear ear protection!
Triaxial vibration value (vibration vector sum)
measured in accordance with EN 60745-2-1 prAA: 2005 Drilling in metal, (a
measured in accordance with EN 60745-2-6 prAB: 2005 Hammer drilling in concrete, (a
Uncertainty (K) for triaxial vibration value
Right of technical modification reserved
16
Printed: 07.07.2013 | Doc-Nr: PUB / 5071102 / 000 / 00
TE6-S
650 W
100 V, 110 V, 120 V, 220 V, 230 V, 240 V
6.5 A, 5.9 A, 5.4 A, 3.0 A, 2.8 A, 2.7 A
50–60 Hz
3.1 kg
320×215×75 mm
0–880 r.p.m.
0–5100 1/min.
0–2700 1/min.
1.8 Nm (J)
0.6 Nm (J)
4–24 mm dia.
5–20 mm dia.
25–68 mm dia.
5–13 mm dia.
5–22 mm dia.
25–68 mm dia.
8 mm dia. = 28 cm
3
/min.
12 mm dia. = 45 cm
3
/min.
16 mm dia. = 49 cm
3
/min.
Protection class II (double insulated) Z
As per EN 55014-2
As per EN 55014-1
98 dB(A)
87 dB(A)
)
h, D
2.5 m/s
2
)
11.0 m/s
2
h, HD
1.5 m/s
2

Publicidad