Descargar Imprimir esta página

GE MGI09CABC3 Manual De Uso Y Cuidado página 113

Publicidad

Idiomas disponibles

Idiomas disponibles

• Do not let wires touch or rest against refrig-
erant tubing, the compressor, or any mov-
ing parts within the unit.
• If the unit has an auxiliary electric heater, it
must be installed at least 1 meter (40 in)
away from any combustible materials.
WARNING: BEFORE PERFORM-
ING ANY ELECTRICAL OR WIR-
ING JOB, TURN OFF THE MAIN
POWER TO THE SYSTEM.
1. Prepare the cable for connection:
USE THE RIGHT CABLE
• Indoor power cable (if applicable):
H05VV-F or H05V2V2-F.
• Outdoor power cable: H07RN-F.
• Signal Cable: H07RN-F.
Minimum cross section area of power and
signal cables.
North America
Appliance amperage
10 A
13 A
18 A
25 A
30 A
Other Regions
Appliance Rated
Current (A)
> 3 and > 6
> 6 and < 10
> 10 and < 16
> 16 and < 25
> 25 and < 32
> 32 and < 40
a. Using wire strippers, strip the rubber
jacket from both ends of cable to expose
about 40 mm (1.57 in) of the wires inside.
b. Strip the insulation from the ends of the
wires.
c. Using a wire crimper, crimp u-lugs on
the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly
distinguish the Live ("L") wire from the rest.
WARNING: ALL WIRING MUST
BE PERFORMED STRICTLY IN
ACCORDANCE WITH THE WIR-
ING DIAGRAM LOCATED INSIDE
THE OUTDOOR UNIT'S WIRE
COVER.
2. Unscrew the electrical wiring cover and re-
move it.
3. Unscrew the cable clamp below the termi-
AWG
nal block and place set it aside.
18
4. Match the wire colors/labels with the la-
16
bels on the terminal block, and firmly
screw the u-lug at the end of each wire to
14
its corresponding terminal.
12
5. After checking to make sure every connec-
10
tion is secure, loop the wires around to
prevent rain water from flowing into the
terminal block.
6. Using the cable clamp, fasten the cable to
Nominal Cross
the unit. Screw the cable clamp down
Section Area
tightly.
0,75 mm²
7. Insulate unused wires with PVC electrical
1 mm²
tape. Arrange them so that they do not
touch any electrical or metal parts.
1,5 mm²
8. Replace the wire cover on the side of the
2,5 mm²
unit, and screw it in place.
4 mm²
6 mm²
113

Publicidad

loading

Este manual también es adecuado para:

Mgi12cabc3Mgi12cdbc3Mgi18cdbc3Mgi24cdbc3