Idiomas disponibles

Installation Kits Contents
A
E
D
Suggested Tool Requirements
SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL
Installation
CAUTION
To avoid the possibility of personal injury, unplug
power to unit before installing or servicing.
Carefully remove air conditioner from carton, check
for possible shipping damage. Pick a location which
will allow you to blow the cold air into the area you
want. Windows used for installation must be strong
enough to support the weight of the air conditioner.
Good installation with special attention to the proper
position of the unit will lessen the chance that service
will be needed.
When cooling more than one room, installation
location is very important. To cool your rooms, cold air
must be blown from the air conditioner in a straight
path.
If air conditioner is blocked by a storm window frame,
see Step 7 and 8 on Page 14 before beginning to
install.
B
C
G
F
H
ITEM
NAME OF PARTS
A
SUPPORT, BRACKET
B
LEVELING BOLT
C
LEVELING BOLT
D
SCREW: 5/8"
E
SCREW: 5/8"
F
FOAM SEAL
G
FOAM STRIP
H
L BRACKET
How to Install
1
Cut the FOAM STRIP (ITEM G) to fit the
underside of the window sash. Open the window, peel
off the backing and attach the FOAM STRIP as shown
in FIG. 1.
@@
@@
FOAM STRIP
(ITEM G)
2
Mark center line with pencil on the center of the
inner sill, as shown in FIG. 2.
INDOOR
CENTER LINE
12
Q'TY
1
1
1
2
5
1
1
1
FIG. 1
FIG. 2
INNER SILL