STATUS INDICATOR
Power Button LED Indicator
Solid green
Flashing green (1Hz) for 1
minute, then shuts off
Solid red for 1 min, then
shuts off
Flashing red quickly (2Hz)
for 1 minute, then shuts off
Flashing red slowly (1Hz)
for 1 minute, then shuts off
Working Condition
Standby
The connected USB device(s)
draw(s) no more than 2W
and the connected AC device
draws less than 5W.
Powering connected devices
Low battery voltage
The power inverter or battery
pack is overheated.
The power inverter may be
overloaded or short circuited.
Other electronics error.
56-VOLT POWER INVERTER — PAD1800/PAD1800-FC
Action
Normal operation. The
power inverter will shut
off automatically in 2
hours if there is no device
connected.
The power inverter could
still power the devices but
will shut off automatically
in 2 hours.
If this happens, turn the
power inverter back on.
Normal operation.
Charge the battery. See
"LOW BATTERY PACK
CHARGE PROTECTION"
below.
Allow the unit to cool
down, then restart the
power inverter. See
"OVER TEMPERATURE
PROTECTION" below.
Disconnect device from
the AC output port, see
"OVERLOAD OR SHORT
CIRCUIT PROTECTION"
below.
Disconnect your device and
reconnect it again, if the
same fault reoccurs, please
contact EGO customer
service center.