SERVICING MACHINE
All repairs must be performed by a qualified service technician.
FOR SAFETY: When servicing
machine, unplug cord from wall outlet.
Wear appropriate personal protection
equipment as needed.
The machine is designed to hinge open for ease of servicing.
To access the internal components, remove the two lock plates
at back of machine and carefully hinge open machine. Empty
tanks before opening machine. Reconnect the vacuum hose
when closing machine. Replace lock plates.
STORING MACHINE
1.
Remove all water from solution tank by using the hose from
the machine to vacuum water into the recovery tank.
2.
Drain and rinse out recovery tank.
3.
Attach solution hose to machine and wand. Turn on pump
and hold lever on wand to run pump dry. Turn off pump.
4.
Disconnect power cord from machine. Neatly coil the power
cord and store on machine.
5.
Store extractor with tank covers off to promote air circula-
tion.
6.
Store machine in dry area.
WARNING: Do not expose to rain. Store
indoors only.
ATTENTION: If storing machine in freezing tempera-
tures be sure that machine solution system and pump
are completely drained and dry.
Tennant EC2 (01/2014)
Vacuum
Hose
LOADING MACHINE
Load machine with assistance by utilizing the 2 top loading
wheels as shown. Secure machine with tie down straps. Empty
solution tank and recovery tank before loading machine.