4.
Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
5.
Move the On/Auto/Off switch to
"On/Auto" position. The compres-
sor will start.
6.
Run the compressor for 20 min-
utes. Make sure the drain valve
is open and there is minimal air
pressure build-up in tank.
7.
After 20 minutes, close the drain
valve by turning clockwise. The air
receiver will fill to "cut-out"
pres-
sure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up
1.
Set the On/Auto/Off switch to
"Off".
2.
Pull regulator knob out, turn
counterclockwise
until it stops.
Push knob in to lock in place.
3.
Attach hose and accessories.
NOTE: The hose or accessory will
require a quick connect plug if the
air outlet is equipped with a quick
connect socket.
Risk of unsafe
_
--
'--
operation.
Firmly
grasp air hose in hand when
installing or disconnecting
to
prevent hose whip.
_Risk
of unsafe
operation. Do not
use damaged
or worn accessories.
_Risk
of Bursting.
Too much air
pressure causes a hazardous
risk of
bursting.
Check the manufacturer's
maximum
pressure rating for air
tools and accessories.
The regulator
outlet pressure must never exceed
the maximum
pressure
rating.
_Risk
of unsafe
operation.
Compressed
air from the unit may
contain water condensation
and
oil mist. Do not spray unfiltered
air
at an item that could be damaged
by moisture.
Some air tools and
accessories
may require filtered
air. Read the instructions for the air
tools and accessories.
How to Start
1.
Set the On/Auto/Off switch to
"On/Auto" and allow tank pressure
to build. Motor will stop when tank
pressure reaches "cut-out" pres-
sure.
2.
Pull the regulator knob out and
turn clockwise to increase pres-
sure. When the desired pressure
is reached push knob in to lock in
place.
If any unusual
"
"__
noise or vibration
is noticed, stop the compressor
immediately
and have it checked
by
a trained service technician.
The compressor is ready for use.
17-ENG
1000003598