Service
7
Blade Care
Chipper Blades
WARNING;
Always stop engine, disconnect
spark
plug, and ground
against engine
before cleaning,
lubricating
or doing any kind of maintenance
on
your machine.
1.
2.
3.
Disconnect
the spark plug wire and ground
against the
engine.
Remove the flail screen as instructed
in the previous
section.
Remove the chipper
chute by removing
three hex nuts and
washers. See Fig. 7-1A.
//
/
iJ
/
/
/
/
/
/
/
Figure 7-1
4.
Remove the chipper
chute support
brace (Model Series
460) from the frame by removing
the hex bolts. See Fig.
7-1B.
5.
Rotate impeller
assembly
by hand until you locate one of
two chipper
blades in the chipper
chute opening.
6.
Remove the blade by removing
the internal
hex screws,
lock washers, and hex nuts which secure it to the impeller.
See Fig. 7-2. Retain the hardware.
f
/
/
7.
8.
Figure 7-2
NOTE: Use a 3/16" hex key (Allen) wrench
on the outside
of
the blade and a 1/2" box (or socket) wrench
on the inside of
the impeller.
Hold the Allen wrench
stationary
and rotate
the box (or socket) wrench
to loosen the nut.
Install a replacement
blade (Part No. 781-0490) with the
hardware
removed
earlier or sharpen.
IMPORTANT:When
sharpening
the blade, protect
hands by
using gloves. Follow the original
angle of grind and make
sure to remove an equal amount
from each blade.
To replace the other blade, rotate the impeller
to expose
the second
blade and repeat the steps above.
NOTE:Make
certain
blades are reassembled
with the sharp
edge facing upward. Torque hardware
to 250 - 300 in. Ibs.
_k
WARNING:
The impeller's
chipper
blades and
shredder
blade are sharp. Wear leather work gloves
to protect
your hands.
15