Idiomas disponibles

Typical Under
Oven
Counter
Installation
of an Electric Built-in
with a Cooktop
Mounted
Above
All mounting
hardware
must be
used to secure the built-in oven to
the cabinets. Refer to the built-in
oven installation instructions.
Junction box must
be located approx.
3" (7,6 cm) to the
left of the built-in
oven cutout.
This cooktop may be
installed over certain
built-in electric oven
models.
Side filler panels are necessary to isolate
the unit from adjoining cabinets. Panel
height should allow for installation of
approved cooktop models. See "Typical
Gas Cooktop Installation Over an
Electric Built-in Oven Installed Under the
Counter" on next page.
208/240 Volt
grounded junction
box for built-in oven.
Cut an opening in wood base minimum 4"
(10,2 cm) x 4" (10,2 cm) to route armored
cable to junction box.
Unit will
overlap
cutout
(minimum)
edges by
1" (2.5cm)
36
"
(91,4 cm)
Min.
Use 3/4" (1,9 cm)
plywood, installed on
two runners, flush with
toe plate. Base must be
capable of supporting
150 pounds (68 kg) for
27" models and 200
pounds (90 kg) for 30"
models.
4 1/2" (11,4 cm)
Max.*
If no cooktop is installed
directly over the oven unit,
5" (12,7 cm) maximum is
allowed.
E
F
OVENSIZE
Min.
Max.
Min.
I
Max.
30"
27 ¼"
28 ¼"
28 F2"
29"
23 F2"
(76,2 cm)
(69,2 cm)
(71,8 cm)
(72,4 cm)
(73,7 cm)
(59,7 cm)
27"
27 ¼"
28 ¼"
24 %"
25 ¼"
23 F2"
(68,6 cm)
(69,2 cm)
(71,8 cm)
(63,2 cm)
(64,1 cm)
(59,7 cm)
Figure 3