Descargar Imprimir esta página

HIKOKI RP 350YBL Instrucciones De Manejo página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
12.2 Reduction in suction power
If the suction power decreases, carry out the
following steps:
1. Clean the filter cassettes by activating the
electromagnetic vibrator (set switch (2) to the
"IR" position).
2. Empty the container or replace the fleece filter
bag (5) or PE disposal bag (sold separately).
3. Replace the filter cassettes (14).
12.3 Renew the filter cassettes (14)
Shake the filter cassettes (14) once again before
replacing the filters, by switching on the
electromagnetic vibrator (set switch (2) to the "IR"
position).
Use a coin or a similar object to turn the locking
knob (12) on the locking bar (11) counter-clockwise
through 90° and push the bar (11) to the rear. Swing
up the hood and pull up the filter cassettes (14) to
remove them. Seal the removed filter cassettes
immediately in a dust-tight plastic bag and dispose
of them in accordance with regulations. Insert new
filter cassettes, ensuring they are correctly and
securely in place.
12.4 Motor protection filter
Regularly check the motor protection filter. If the
motor protection filter (13) is contaminated, this
indicates that the filter cassettes (14) may be
defective:
- Replace the filter cassettes (14).
- Replace the motor protection filter (13), or rinse it
under running water, dry it and then replace.
12.5 Water sensor
IMPORTANT - Clean the water
sensor regularly and check it for
signs of damage.
13. Troubleshooting
If the volume flow control display (3) flashes, this
indicates that the fleece filter bag must be emptied.
Reduction in suction power:
See the instructions in the section on Cleaning.
• Filter cassettes (14) soiled? - clean.
• Fleece filter bag (5) full? - replace.
• PE disposal bag (sold separately) full? - replace.
• Container (9) full? - empty.
• Motor protection filter (13) clogged? - See
chapter 12.
• Nozzle, tubes or hose blocked?- clean.
Device will not start:
• Is the plug in the plug socket?
• No power from mains?
• Mains lead OK?
• Device hood correctly closed?
• Has the water sensor cut off? - Empty the
container; then switch on and off again.
• Switch (2) in "AR" position? - Set to "I" or "IR".
See chapter 9.1.
• The dust extractor is not switched on or off by
means of a power tool, even though switch (2) is
set to the "AR" position. - Connect the power tool
to the plug socket (4).
Dust in the container when fleece filter bag is
fitted:
• The position of the rotary slide is incorrect. See
chapter 8.1.
PE disposal bag is sucked to the filter
cassettes (14):
• The position of the rotary slide is incorrect. See
chapter 8.2.
14. Accessories
Use only genuine HiKOKI accessories. See
page 182.
Use only accessories that fulfil the requirements
and specifications listed in these operating instruc-
tions.
15. Repairs
Replacing supply cord
If the replacement of the supply cord is necessary,
it has to be done by HiKOKI Authorized Service
Center to avoid a safety hazard.
CAUTION! In the operation and maintenance
of power tools, the safety regulations and
standards prescribed in each country must be
observed.
English
9

Publicidad

loading