Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart
of this cooling system is an
engineered fan. It is perfectly normal
for this fan to blow air through the
vent holes in large amounts. You
know that the cooling system is
working when air is being expelled.
Air Compressor
Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
compressor is operating,
the check
valve is "open", allowing compressed
air to enter the air tank. When the air
compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Check Valve
Release
Valve
Air Intake Filter (not shown)
This
filter is designed to clean air coming
into the pump. This filter must always
be clean and ventilation openings
free from obstructions.
See
"Maintenance".
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off lever to
"OFF".
Before
First Start-up
Risk of Unsafe
Operation. Serious
damage
may result if the following
break-in instructions are not
closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor
pump has been
replaced.
Break-in
Instructions
1.
Make sure the On/Auto/Off
lever
is in the "OFF" position.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph
in the
Installation section of this
manual.)
Pressure Release Valve:
The
pressure release valve, located on the
side of the pressure switch, is
designed to automatically
release
compressed
air from the compressor
head and the outlet tube when the air
compressor reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds.
No air should be heard leaking when
the motor is running or after unit
reaches "cut-out"
pressure.
3.
4.
5.
Open the drain valve fully
(counterclockwise)
to permit air
to escape and prevent air
pressure build-up in the air tank
during the break-in period.
Move the On/Auto/Off
lever to
"ON/AUTO"
position. The
compressor
will start.
Run the compressor for 20
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up
in
tank.
15- ENG
D30090