Motor
This motor has a manual thermal
overload protector. If the motor
overheats for any reason, the
overload protector
will shut off the
motor. The motor must be allowed to
cool down before restarting.
To
restart:
1.
Place the On/Auto/Off
lever in
the Off postion.
2.
3.
4.
Allow the motor to cool.
Depress the red reset button on
the motor.
Place the On/Auto/Off
lever in
the On/Auto postion to restart
the motor.
To Replace
Belt
_[_
Risk from Moving
Parts. Serious injury
or damage may occur if parts of
the body or loose items get caught
in moving parts. Never operate the
unit with the belt guard removed.
The belt guard should be removed
only when the compressor is
unplugged.
1.
Disconnect
electrical supply to
the air compressor
2.
Remove the front of the belt
guard by disengaging
the snaps.
Insert a flat bladed screwdriver at
each snap location and pry the
beltguard apart.
3.
Loosen the wing nut on hold
down plate and tilt motor to
allow for easy removal or
installation of the belt.
4.
Remove belt.
5.
Replace belt. NOTE: The belt
must be centered over the
grooves on the flywheel and
motor pulley.
6.
Turn the wing nut on the hold
down plate until it makes contact
with the washer, plus one
additional turn.
7.
Replace the belt guard.
21_ ENG