Descargar Imprimir esta página

Scheppach HC06 Traduccion Del Manual De Instrucciones Originale página 24

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
8.5 Using the tyre inflater
The compressed air tyre inflation device (13) is used to
inflate car tyres. With the corresponding accessories it
can also be used to inflate and regulate bicycle tyres,
inflatable dinghies, air mattresses, balls etc.
Pressure can be released by actuating the vent valve.
Important! The manometer has not been officially cal-
ibrated!
After inflating, please check the air pressure with a
calibrated device.
8.6 Using the air blow gun
You can also use the air blow gun (12) to clean out cav-
ities and to clean soiled surfaces and work equipment.
Always wear protective goggles when doing so!
8.7 Using the adapter set
The adapter set enables you to use the following addi-
tional capabilities of the tyre inflation device:
Pumping up balls with the help of the ball needle (9).
The valve adapter (10) enables bicycle tyres to be in-
flated.
Filling pools, air mattresses or boats with the help of
the additional adapter (11).
9.
Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cable used must also comply with these
regulations.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
24 | GB
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly.
Make sure that the connection cable does not hang on
the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
10. Cleaning, maintenance, storage
and spare-part ordering
m Important!
Pull out the power plug before doing any cleaning and
maintenance work on the equipment. Risk of injury
from electric shock!
m Important!
Wait until the equipment has cooled down completely!
Risk of burns!
m Important!
Always depressurize the equipment before carrying
out any cleaning and maintenance work! Risk of injury!
10.1 Cleaning
• Keep the equipment free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or
blow it down with compressed air at low pressure.
www.scheppach.com
.
²

Publicidad

loading

Este manual también es adecuado para:

5906132901