CoolFreeze CDF11
6.13
Replacing the plug fuse (12/24 V)
➤ Pull the adapter sleeve (fig. 3 4, page 4) off of the plug.
➤ Unscrew the screw (fig. 3 5, page 4) out of the upper half of the housing
(fig. 3 6, page 4).
➤ Carefully raise the upper half of the housing from the lower (fig. 3 1, page 4)
half.
➤ Take out the contact pin (fig. 3 3, page 4).
➤ Replace the defective fuse (fig. 3 2, page 4) with a new one that has the same
rating (T8A 32V).
➤ Re-assemble the plug in the reverse order.
7
Cleaning and maintenance
!
WARNING!
Always disconnect the device from the power supply before you clean
and service it.
A
NOTICE! Risk of damage
• Never clean the cooler under running water or in dish water.
• Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooler.
➤ Occasionally clean the device interior and exterior with a damp cloth.
➤ Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
EN
Cleaning and maintenance
17