Technical Data
Note: The voltage levels before/after the slash are valid for 12 V and 24 V systems respectively.
Technical Data
System voltage
Max. charge current
Float charge
Main charge
Boost charge
Equalization charge
Deep-discharge protection
Reconnect level
Overvoltage protection
Undervoltage protection
Max. PV panel voltage
Max. usable PV power
Max. PV array power
Temperature compensation (charge voltage)
Idle self-consumption
Grounding
www.phocos.com
CIS-N-MPPT-LED 85/15
12/24 V auto recognition
15 A
13.8/27.6 V (25 °C)
14.4/28.8 V (25 °C), 0.5 h daily
14.4/28.8 V (25 °C), 2 h, activation: battery voltage < 12.3/24.6 V
14.8/29.6 V (25 °C), 2 h, activation: battery voltage < 12.1/24.2 V (at least every 30 days)
11.0-12.0/22.0-24.0 V (by SOC)
11.0-11.9/22.0-23.8 V (by voltage)
12.8/25.6 V
15.5/31.0 V
10.5/21.0 V
50/85 V
225 W @ 12 V, 450 W @ 24 V
250 Wp @ 12 V, 500 Wp@ 24 V
-25 mV/K @ 12 V / -50 mV/K @ 24 V
< 10 mA
Common negative