Troubleshoot Guide
No.
Problem/Issue
1
Insufficient suction
Suction is too small
2
Cause Analysis
Test the suction power:
Separate the main body from the cup, put the main body in the palm of your hand,
Host failure
and check whether there is suction in the palm of your hand. If there is suction, the
machine is not the problem. Otherwise, the problem lies with the main unit.
Check for installation issues:
1. To ensure proper assembly and a complete seal, follow the instructions provided to
reassemble the fitting correctly.
Improper
2. Wash and dry the flange, look for damage, and see if disinfection has altered its
installation
appearance.
3. Verify whether the installation method is incorrect and whether the duckbill valve
is damaged.
Not tightly fitted
To ensure the flange and breast are properly fitted together during breastfeeding,
to the breast
follow the instructions for correct sitting posture provided.
It's important to note that low suction can result in no milk being expressed during pumping. The
baby's natural sucking pressure typically ranges from 10 to 45 kPa, and the international standard for
breast pumps is a maximum suction pressure of 40 kPa. If this pressure is exceeded, it can damage the
capillaries in a woman's breast. However, with Nuliie's breast pump, the suction pressure falls within the
safe range of 10-45Kpa, which is similar to a baby's natural sucking pressure.
After ensuring that the new breast pump is functioning correctly, select the
appropriate mode and gear. The atmosphere, your mood, and your physical
New machine
condition may affect your milk flow. To increase milk production, consider using a
warm compress with a towel. Generally, it doesn't matter if you utilize breast pumps
from different brands.
The primary causes of issues are deformation from cleaning and improperly installed
accessories. Consumable components include silicone diaphragms and duckbill
valves. It is advisable to change them every three to six months. You might try the
Suction power
following measures to see if the suction force decreases:
decreases with
1. Examine the accessories for damage or significant deformation.
prolonged use
2. Assemble the accessories and ensure they are fully sealed following the provided
instructions.
3. Ensure the silicone diaphragm is fully contracted and adjust to the breast
pumping mode's highest gear.
Solution
12
English