WARNING
Read all safety warnings, instructions, illustrations
and specifications provided with this product.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
Safety notes
Safety extra low voltage 24 V DC!
Do not connect directly to the mains supply!
- Connection has to be carried out only by an
authorized electrical specialist
- Danger of violent pressure in handaccessible area
- Keep away People from the operating area of the
drive
- Keep away children from the control
- Observe pressure load diagram of the chain!
- Use only in dry rooms
- Only for inside mounting.
Use rain detector with danger of rain
(e.g. at domelights or roof windows)
- This product may not be operated without the
covering stoppers, which are delivered with
bracket sets
- Just use unchanged original D+H parts
- Observe mounting instructions of bracket set!
Observe enclosed r ed safety slip!
Functional description
A synchronous group (KA-BSY+) can contain up to 8
drives, which communicate via bus. Each drive has
its own address, configurable with SCS.
The drive with the highest adress in a synchronous
group is the main drive. The main drive controls
the other drives, the sub drives. Differences in
forces between the drives of a group are balanced
by means of intelligent force and position control.
In the event that a drive malfunctions, all the drives
are automatically cut off.
6/20
KA-BSY+
Intended use
- Chain drive for electric opening and closing of
windows and flaps in the facade and roof area
- By VdS is the maximum load for the chain
at pressure = 600 mm and at tension = 1000 mm
- Operating voltage 24 V DC
- Useable for smoke ventilation, D+H Euro-SHEV
according to DIN EN 12101-2 as well as daily
natural ventilation
- Only for inside mounting
Performance features
- Micro processor controlled synchro electronics
BSY + for a precise synchronous run of up to
8 drives
- Individually programmable (via software SCS)
- SHEV-high speed function (fast-running
feature in OPEN-direction)
- Protection system for the main closing edge
- Power supply and BSY+ signal can be looped
through: with KA 34-BSY+ for max. 3 drives, with
KA 54-BSY+ for max. 2 drives
- Power supply is possible from both sides
- Locking relief after closing
Extent of supply
Drive unit with 2,5 m silicone cable. Dependent on
the type of window, different bracket sets are
available separately.
Pressure load diagram
Observe maximum pressure load of the chain!
Maximum pressure load of the chain is not
automatically identical with maximum pressure force
of the drive!
500
400
300
200
100
0
KA 54-BSY+
English
Stroke / (mm)
KA 34-BSY+
99.823.89 3.0/09/23