Mounting information
The drive will be full configured by factory.
The drives must be reconfigured in case of
alterations (e.g. removing of drives
from existing set or integrating
a new drive) with SCS.
A t v e r t i c a l a c t i v e p u l l i n g
application (e.g. for a skylight) the
forces must be rearranged by
software SCS
Shift of drive cable
DIP-Switch
Only for ex-works programming
Debe ser encendido OFF
8/120
KA-BSY+
Mount the drives mechanical stress-free.
With that, a better load distribution
is ensured on all the drives.
Sub 1
If after mounting the measure x is
as bigger as 23 mm, null balance
with software SCS is neccesary.
Closure Ranges will shift in
relation to new zero point.
X
If factory-set locking pressure of ca. 150 N is not
sufficient to close the window, it can be infinitely
increased up to ca. 250 N.
Put in covering stopper after adjustment.
Locking force adjustment
English
For option "IP 42": the chain
outlet must not point upwards.
≥ 23 mm ?
Locking force adjustment
approx. 150 N
99.823.89 3.0/09/23
Ø 6 mm
approx. 250 N