finally assemble the new filter into the blower. Inserting a new filter: Put the filter back into position and
gently push until it fits well on the body of the unit.
Closing the filter Cover; simply snap the cover into place. Pay special attention to snap the cover properly
into the blower. Do not attempt to use the blower unit without the cover fitted correctly.
WARNING!
It is essential that the user must not confuse the markings on the filter relating to any other standard other
than EN12941:1998 + A1:2003 + A2:2008 with the classification of the device when used with this filter. The
filters must be regularly checked (see Air Flow Test) and replaced. Filters are intended to be replaced and not
cleaned / re-used.
MAINTENANCE OF THE AIRMAX+ PAPR SYSTEM
• The blower unit, filter housing and head units must all be regularly cleaned to keep them in good working
order.
• For single users, the units can be cleaned with a cloth moistened with warm water and soap or an antimi-
crobial wipe.
• For multiple users, the units should be disinfected when passed from one user to another.
• Liquids must not be allowed to enter the workings of the blower unit or get on to the element of the filter.
Parts should be allowed to air dry. Under no circumstances should any solvents or abrasive cleaning
agents be used. The unit must not be dried using heat.
• The unit should continue to provide protection to the designed specification for at least 3 years when
maintained in accordance with these instructions. The duration of use depends on various factors such as
type of use, cleaning, storage and maintenance.
Shelf Life from date of manufacture when stored in original packaging
1. Motor Unit/Blower
2. Battery pack (Standard + HD)
3. P R SL filter
4. Head top
5. ADF (Auto Darkening Filter
• Prior to each use the user should check that all components of this system are free from defects, such as
burnt areas, holes, splits or broken filters and hoses, cracked visors, ADF's and helmets.
If additional cleaning is required, leave in the filter/cartridge and breathing tube. To minimize material falling
onto the motor/blower. The Airmax+ can now be showered under running water but not immerse, or put in a
respirator. Water temperature should not exceed 122°F (50°C). Blowers which have been dropped or dam-
aged should not be showered due to potential water ingress. Once the unit has been showered and dried the
filter is to be disposed of and not reused.
CHARGING THE BATTERY
Once the unit has reached the Minimum Design Flow
(MDF), it is better to leave it to run down completely be-
fore recharging. The battery can either be charged whist
installed in the blower unit or removed and charged
separately. Plug the charger into the main socket, fit the
plug on the end of the lead into the socket at the back of
the battery. The charger unit is a smart charger meaning
that once the battery is fully charged the charger unit
under the recommended storage conditions
5 years
1 year
5 years
5 years
5 years
9