is upandaligntheholewiththegrounding holebelow
theterminal b lock. U sethegreen grounding s crew(B)
toattach thegreen wire(C)ontopofgrounding s trap.
Tighten thegrounding s crewfirmly, b utdonot
overtighten.
,
Attach the red wire to the left junction block terminal
using one of the nut/washer parts removed in step 2.
iiiiiiiii!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
6.
Attach the white wire to the center junction block
terminal using one of the nut/washer parts.
7.
Attach the black wire to the right junction block terminal
using one of the nut/washer parts.
8.
Tighten all connections securely and replace terminal
block cover.
9.
Properly secure strain relief (see previous section)
Note: DO NOT plug in the range at this time.
Three wire range cord connection (Alternate Method)
The Four Wire Connection (above)is preferred, but where
local codes and ordinances permit grounding through the
neutral and where conversion to four wire is impractical, the
unit may be connected to the power supply via a three wire
connection.
1.
Disconnect electrical power at breaker box.
,
3.
Remove the terminal block cover to expose the
terminal block.
Remove the top nut (has an attached locking washer)
from each terminal post.
Note: DO NOT remove the second nut/washer on each
post. These must stay in place to anchor the internal
wiring attached to the terminal block.
4.
Attach the white wire to the center junction block
terminal using one of the nut/washer parts.
5.
Attach the red wire to the left junction block terminal
using one of the nut/washer parts removed in step 2.
6.
Attach the black wire to the right junction block terminal
using one of the nut/washer parts.
7.
Tighten all connections securely and replace terminal
block cover.
8.
Properly secure strain relief (see previous section).
Note: DO NOT plug in range at this time.
English 10