Three Wire Flexible Conduit Connection
The Four Wire Connection is preferred, but where local
codes and ordinances permit grounding through neutral
and/or conversion to four wire is impractcal, unit may be
connected to the power supply via a three wire connection
1.
Disconnect electrical power at the breaker box.
2.
Remove the terminal block cover to expose the
terminal block.
3.
3. Remove the top nut, star washer, and round washer
from each post.
,
8.
9.
Insert stripped end of red wire into the left lug. Secure
clamping screw.
Insert stripped end of black wire into the right lug.
Secure clamping screw.
Tighten each clamping screw with the appropriate
torque (See table below).
Guage
Torque (in/Ibs)
Torque (Nm)
6
35
3.95
8
25
2.82
10. Properly secure flxible conduit at knockout pa-nel on
range and at supply side junction box. The wiring is
now complete.
Note: DO NOT remove last round washer, last nut or inter-
nal wire leads.
4.
Place one terminal lug (packaged with this manual) on
each post. Replace the star washer and round washer
and secure with 20" (50.8 cm) pounds of torque.
5.
Strip 3/8" (9.5 mm) of insulation om the end of each
wire.
3/8 _
6.
Insert stripped end of white wire into the center lug on
top of the ground strap. Secure the clam-ping
screw.
A
B
Note: DO NOT plug in range at this time.
Complete
the installation
Adjust
Leveling
Legs
,
2.
3.
Make sure circuit breaker is off and then plug range
cord into electrical outlet.
Line up range in front of opening.
Measure (A) back left corner of opening from floor to
the top of the countertop.
English 12