The operation of the equipment is controlled in its entirety by the digital
thermostat, which allows for the selection of the temperature and controls the
operation of the lighting (if any).
Connect the equipment to the mains. If "OFF" appears in the digital display, press
the ON/OFF button for 3 seconds.
The factory set point on positive refrigerated equipment is +2 °C, and can be
adjusted on the thermostat between -2ºC and + 8ºC.
The factory set point on positive cold equipment for Fish is + 2 °C, and can be set
on the thermostat between 0ºC and + 5ºC.
In the negative cold models, the factory set point is -20 °C, and can be adjusted in
the thermostat between -10ºC to -22ºC.
The thermostat is locked at the factory, allowing only the set point to be adjusted.
To do this, press the "Set" key, after the programmed value starts to blink, get to
the desired value with the "" ▲ "and" ▼ keys "and press the" Set "key again to set
the value.
The following messages may appear on the thermostat:
Message
To switch off, press the ON/OFF button (information "OFF" on the display,
equipment off) or disconnect the plug from the mains. Wait 10 minutes before
turning the equipment back on.
38
Operating Messages
P1
P2
P3
HA
Maximum Temperature Alarm
LA
Minimum Temperature Alarm
dA
EA
CA
Severe External Alarm (i2F=bAL)
CA
rtc
rtF
Real Time Clock Plate Failure
Description
Ambient Probe Failure
Evaporator Probe Failure
Third Probe Failure
Open Door
External Alarm
Pressure Alarm (i2F=bAL)
Real-time clock