FLASH
FAULT NAME
CODE
OX72
PDO Timeout
0X73
Stall Detected
0X77
Supervision
0X79
Supervision Input Check
0X82
PDO Mapping Error
0X83
Internal Hardweare
0X87
Motor Characterizations
Error
0X88
Encoder Pulse Error
0X89
Parameter Out of Range
POSSIBLE CAUSES
1. The time between CAN PDO
messages received exceeded the
PDO Timeout Period as defined by
the Event Timer parameter.
2. Adjust PDO Settings. See
Programmer » Application Setup »
CAN Interface » PDO Setups.
1. Stalled motor.
2. Motor encoder failure.
3. Bad crimps or faulty wiring.
4. Problems with power supply for
the motor encoder.
5. See Programmer »System Monitor
menu » AC Motor » Motor RPM.
1. Internal controller fault.
1. Internal controller fault.
1. The PDO Map has too many
data bytes assigned or has objects
mapped that are not compatible.
2. Adjust PDO Settings. See
Programmer » Application Setup »
CAN Interface » PDO Setups.
1. Internal controller fault detected.
1. Motor characterization failed
during characterization process.
See fault type for cause.
1. Encoder Steps parameter does not
match the actual motor encoder.
2. Verify parameter settings: AC
Motor Setup » Quadrature Encoder
» Encoder Steps.
3. Motor lost IFO control and accel-
erated without throttle command.
1. Parameter value detected outside
of the limits.
2. Use CIT to view and write param-
eter value and range.
281
SET/CLEAR CONDITIONS
Set: Time between CAN PDO
messages received exceeded
the PDO Timeout Period.
Clear: Receive CAN NMT
message, or Reset Controller.
Set: No motor encoder move-
ment detected.
Clear: Either Reset Controller,
or if parameter LOS Upon
Encoder Fault = On and
Interlock has been cycled,
then the Stall Detected fault
is cleared and the Encoder
LOS fault (flash code 9-3) is
set, allowing limited motor
control.
Set: Internal controller failure
Clear: Reset Controller.
Set: Damaged Controller.
Clear: Reset Controller.
Set: Incorrect PDO map
detected.
Clear: Reset Controller.
Set: Internal controller fault
detected.
Clear: Reset Controller.
Set: Motor characterization
failed during the motor char-
acterization process.
Clear: Reset Controller.
Set: Detected wrong setting of
the Encoder Steps parameter.
Clear: Ensure the Encoder
Steps parameter matches the
actual encoder; Reset
Controller.
Set: Parameter detected
outside of limits
Clear: Bring parameter within
its limits.