OPERATING INSTRUCTIONS
TURNING LASER BEAMS ON/OFF
2
Push the ON/OFF buttons for the X-Plane 1 , Y-Plane
, and Z-Plane 3
lines to turn ON and OFF their respective laser lines. These buttons are only
active once the Pendulum Lock/Unlock Slider Switch 9 has been set to the
Unlocked position. If the Pendulum Slider Switch is moved from the Unlocked
to the Locked position while the laser beams are active, they will be turned
OFF. The different laser lines can be operated independently or simultaneously.
X-Plane Laser Line
Y-Plane Laser Line
Z-Plane Laser Line
NOTE: The plumb spot can be found by locating the top and bottom laser
line intersections while projecting both Y-Plane and Z-Plane Laser lines
simultaneously. The bottom laser line intersection can be used to locate a
specific point on a floor layout while the top laser line intersection projects
that same point to a ceiling.
PENDULUM SLIDER SWITCH & SELF-LEVELING
The laser assemblies are mounted on a pendulum so that the instrument
can self-level. The Pendulum Slider Switch 9 must be in the unlocked
position for the instrument to self-level. If the instrument is tilted by >4°
from the horizontal plane, the pendulum will not be capable of self-leveling;
the active laser beams will flash to indicate that the instrument is not level
and cannot self-level. The instrument must be repositioned on a more level
geometry for the self-leveling pendulum to function appropriately.