Installation
Preparation for installation
CAUTION
Material damage through incorrect installation
Allow only qualified staff to perform the installation.
1. Place the device on a level surface.
2. Switch off the device.
Note
After installation, keep the installation instructions and the circuit
diagram together with the operating instructions.
Wiring diagram
Fresh water tank
1
Detergent container with suction lance
2
Cleaning head
3
Detergent dosing pump
4
Water pump
5
Flowmeter
6
Electric ball tap
7
T-piece
8
Detergent dosing pump and flowmeter
1. Tilt the driver's seat forward and secure it.
2. Close the ball tap.
3. Unscrew the screw (2x) underneath the electrical cabinet.
4. Release the cable clamp.
5. Pull off the hose.
6. Fasten the flowmeter.
Note
Screw in the screws from below.
English
7