Descargar Imprimir esta página

GE Profile 22 Manual Del Propietario E Instalación página 36

Ocultar thumbs Ver también para Profile 22:

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Instructions
INSTALLING THE WATER LINE
(CONT.)
_] FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe
with the pipe clamp.
Pipe Clamp _,
Saddle-Type
Shutoff Valve
_--- Vertical Cold Water Pipe
NOTE: Commonwealth
of Massachusetts
Plumbing Codes 248CMR shall be adhered to.
Saddle valves are illegal and use is not permitted
in Massachusetts.
Consult with your licensed
plumber.
[_] TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing
washer begins to swell.
NOTE: Do not overtighten
or you may crush
the tubing.
Washer
Pipecla m P._
_ClampX_
_nlet
End
Scre_
_)
I
[_] ROUTE THE TUBING
Route the tubing between the cold water line
and the refrigerator.
Route the tubing through
a hole drilled in the
wall or floor (behind the refrigerator
or adjacent
base cabinet) as close to the wall as possible.
NOTE: Be sure there is sufficient
extra tubing
to allow the refrigerator
to move out from
the wall after installation.
rfl
@
CONNECT THE TUBING TO THE VALVE
Place the compression
nut and ferrule (sleeve)
for copper tubing onto the end of the tubing and
connect
it to the shutoff valve.
Make sure the tubing is fully inserted into the
valve. Tighten the compression
nut securely.
For plastic tubing from a GE SmartConnecf
_
Refrigerator
Tubing kit, insert the molded end
of the tubing into the shutoff valve and tighten
compression
nut until it is hand tight, then
tighten one additional
turn with a wrench.
Overtightening
may cause leaks.
Saddle-Type
Shutoff Valve
Packing Nut
Outlet Valve
Compression Nut
_/
SmartConnect"
,_ _
Tubing
Ferrule (sleeve)
NOTE: Commonwealth
of Massachusetts
Plumbing Codes 248CMR shall be adhered to.
Saddle valves are illegal and use is not permitted
in Massachusetts.
Consult with your licensed
plumber.
FLUSH OUT THE TUBING
Turn the main water supply on and flush out the
tubing until the water is clear.
Shut the water off at the water valve after about
one quart (1 liter) of water has been flushed
through
the tubing.
To complete the installation of the refrigerator, go back
to Step 1 in Installing the Refrigerator.
36

Publicidad

loading

Este manual también es adecuado para:

Profile 23Profile 25Profile 26Profile 27Profile 29