Descargar Imprimir esta página

GE Profile 22 Manual Del Propietario E Instalación página 43

Ocultar thumbs Ver también para Profile 22:

Publicidad

Idiomas disponibles

Idiomas disponibles

Performance
Data Sheet
SmartWater
Filtration System-GE ® MSWF Cartridge
This system has been tested and certified in filter model GEMSWFaccording to NSF/ANSI S tandards 42 and 53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI S tandards 42 and 53.* (Safety factors built in for unmetered usage.}
Parameter
'
USEPAMCL
Standard
No. 42: Aesthetic
effects
I
I
influentChallenge
.
Effluent
%Reduction
Concentration
Average
'
Maximum
'
Average
Maximum
Min. Required Reduction
2.0 mg/L ± 10%
0.06 mg/L
0.10 mg/L
97%
9.1%
> 50%
at least 10,000 particles/
408,333
670,000
95.5%
89.4%
> 85%
mL
Standard
No. 53: Health
effects
....
'
in"uentCha,enge ....
Emuent
Parameter
'
USEPAMCL
Concentration
Average
Maximum
Average
Maximum
! NTU....
11+ 1 NTU....
0.38 NTU
0.S NTU
96.5%
95.4%
99.95% Reduction
Minimum 50,000 L
< 1 #/L
4 #/L
> 99.99%
> 99.99%
0.010 mg/L
0.15 mg/L ± 10%
< I ppb
< 1 ppb
99.3%
99.3%
0.010 mg/L
0.15 mg/L ± 10%
3,i ppb
9.0 ppb
98.0%
95.5%
0.002 mg/L
0.006 mg/L ± 10%
0.34 ppb
0.7 ppb
94.0%
89.6%
0.002 mg/L
0.006 mg/L ± 10%
0.66 ppb
1.5 ppb
88.4%
73.7%
0.0002 mg/L
0.002 mg/L ± 10%
< 0.02 ppb
< 0.02 ppb
> 99.0%
> 99.0%
0.003 mg/L
0.009 mg/L ± 10%
<0.5 ppb
< 0.05 ppb
> 93.9%
> 94.3%
0.070 mg/L
0210 my/L_+ 10%
7.7 ppb
35 ppb
96.0%
82.0%
0.003 mg/L
0.015 mg/L _+ 10%
< 1 ppb
< 1 ppb
>92.9%
> 92.9%
0.005 mg/L
0.015 mg/L ± 10%
< 0.S ppb
< 0.5 ppb
>96.8%
> 97.0%
0.040 mg/L
0.080 mg/L ± 10%
< 1 ppb
1 ppb
> 98.7%
> 98.7%
0.075 mg/L
0.225 mg/L _+10%
< 0.5 ppb
< 0.5 ppb
> 99.7%
> 99.8%
99% Reduction
107 to 10 8fibers/L;
< 0.17 HF/L
<0.17 MF/L
> 99%
>99%
fibers > 10pro in length
*Testedusing pressure of 60 psig;pH of 7.5± 0.5;temp of 680± 5%120 ° ±2.5°C}.
**Measurement in Particles/mL. Particles used were 0.5-1microns.
***Based onthe useof Cryptosporidium parvum oocysts.
.... NTU=NephelometricTurbidity Units
Capacity 300 gallons 11,135 liters). Contaminant reduction determined by NSFtesting.
% Reduction
:
Max, Permissible
Product Water
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0,002 mg/L
0,002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0,003 mg/L
0,005 rng/L
0.040 mg/L
0.075 mg/L
99% Reduction
Application
Guidelines/Water
Supply Parameters
ServiceFlow
Water Pressure
WaterSupply
Water Temperature
It is essentialthat the manufacturer'srecommended installation,maintenanceand filter replacementrequirementsbe curriedout for the productto perform asadvertised.
See insert for Warranty information.
Operating
Specifications
®Pressure requirement:
40-120
psi (2.8-8.2 bur), non-shock
• Temperature:
33-100°F (0.6-38°C)
• Flow rate: 0.9 gpm (3.14 Ipm)
General
Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 4-1/2 gallons (about five minutes} to purge
trapped air.
• Replace cartridge
when flow becomes too slow.
• Protect from freezing
by removing
filter cartridge
when temperatures
ore
expected
to drop below 40°F (4.4°C). Do not install systems
in areas where
ambient
temperatures
may go above 100°F or below 40°E Do not install
on a hot water
supply.
Special
Notices
• Installation
instructions
ore included with the product when shipped.
, This drinking water system must be maintained
according to manufacturer's
instructions,
including
replacement
of filter cartridges.
• Do not use with water that is microbio)ogicaUy
unsafe or of unknown quality with-
out adequate
disinfection
before or after the system. Systems certified for cyst
reduction
may be used on disinfected
water that may contain filterable
cysts.
• The contaminants
or other substances
removed
or reduced by this water
treatment
system are not necessarily in your water.
, Check for compliance
with the applicable
state and local tows and regulations.
. Note that while the testing was performed
under standard laboratory
conditions,
actual performance
may vary. Systems must be installed and operated
in
accordance
with manufacturer's
recommended
procedures
and guidelines.
• Installation
and use MUST comply with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa), you should install a pressuredimiting
valve. Contact a plumbing
professional
if you ore uncertain
how to check your water pressure.
Do not install where water hammer conditions
may occur. If water hammer
conditions
exist you must install a water
hammer arresten Contact a plumbing
professional
if you are uncertain
how to check for this condition.
. Where a backflow
prevention
device is installed on a water system, o device for
controlling
pressure due to thermal expansion
must be installed.
For conditions of use, health claims certified by the California Department
of Public
Health, and replacements,
see performance
data sheet. California Department
of Public Health Certification
#06-1834. The contaminants
or other substances
removed or reduced by this water filter are not necessarily
in oil users' water.
Tested and Certified
by NSF International
against
ANSI/NSF
Standards
42 and 53 in model
GE MSWF for the reduction
of:
Standard
Na. 42: Aesthetic
Effects
• Chemical
- Chlorine
Taste and Odor
• Mechanical Filtration
- Particulate Reduction, Class I
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com
Standard
No. 53: Health
Effects
, Chemical
Reduction
- Atrazine
Reduction
- Endrin Reduction
- Benzene
and Corbofuron
Reduction
- 1,4 Dichlorobenzene
and
2,4-D Reduction
- Lead and Lindane Reduction
- Mercury and Toxophene Reduction
• Mechanical Filtration
- Cyst and Asbestos Reduction_-_
REPLACEMENT
ELEMENT
EPA#10350-MN-005
© 2010 General Electric ComDanv
PC61577C
43

Publicidad

loading

Este manual también es adecuado para:

Profile 23Profile 25Profile 26Profile 27Profile 29