Operation instructions for controller
3) Function setting
Press "FUNCTION" icon to enter the function setting interface, shown in Picture 20. In this interface, you can turn on or off
some common functions, and adjusting its working hours. In this interface, you can set following functions.
System functions of user setting
Function
Sterilization
ECO (economy)
Mode
(Difference between energy
saving temperature and
actual temperature.)
Holiday Mode
Setting Temp. of Zone1
Setting Temp. of Zone2
Quiet
Turbo
Fast DHW
DHW Priority
Dry Concrete of Zone1
Dry Concrete of Zone2
IDU Antifreeze Protection
IDU Antifreeze Temp.
Parameter Range
Operation
Week
Monday ~ Sunday
Time
Temp.
Operation
Time
△ T
Operation
Date
Start date ~ End date
Operation
Time1
Start time ~ End time
Time2
Start time ~ End time
Operation
30min/60min/90min/
Timer
Picture 20
Default
On/Off
Off
Monday
00:00~24:00
23:00
50°C~75°C
75°C
On/Off
Off
24 hours
22:00~07:00
-15°C~0°C
-5°C
On/Off
Off
Current date~
Current date
0°C~30°C
15°C
0°C~30°C
15°C
On/Off
Off
Current time~
Current time
Current time~
Current time
On/Off
Off
60min
Continuous
On/Off
Off
On/Off
On
On/Off
Off
On/Off
Off
On/Off
On
0~15°C
5°C
41
Remarks
When the unit is sterilizing,
the sterilization icon is flashing
displayed in the main interface
It's only valid at heating mode.
During the energy-saving
operation of the unit, the outlet
water temperature is △ T lower
than the set temperature.
To save energy, a holiday
period may be set to lower the
temperature during the period.
To operate quietly during the
preset period.
Turbo mode is use to increase the
capacity of heat pump to achieve
higher target temperature.
/
No matter what mode the unit is
in, the domestic hot water shall be
heated first.
/
/
/
/