Descargar Imprimir esta página

Metabo CV 18DA Manual página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

APPLICATIONS
○ Flush cutting and pocket cutting of various materials
○ Peeling of tiles, caulking, etc.
○ Polishing wood materials, etc.
REMOVAL AND INSTALLATION METHOD
OF BATTERY
1. Battery removal
Hold the handle tightly and push the battery latch to
remove the battery (see Fig. 6).
CAUTION
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see
Fig. 6).
Latch
Battery
Push
Insert
CHARGING METHOD
NOTE
Before plugging into the receptacle, make sure the
following points.
○ The power source voltage is stated on the nameplate.
○ The cord is not damaged.
WARNING
Do not charge at voltage higher than indicated
on the nameplate.
If charged at voltage higher than indicated on the
nameplate, the charger will burn out.
ASSEMBLY AND OPERATION
Pull out
Fig. 6
<UC18YFSL>
1. Connect the charger's power cord to a receptacle.
When the power cord is connected, the pilot lamp will
blink in red. (See Table 2)
WARNING
Do not use the electrical cord if damaged. Have it
repaired immediately.
2. Insert the battery to the battery charger.
Firmly Insert the battery into the battery charger as
shown in Fig. 7.
Pilot lamp
3. Charging
When inserting a battery in the charger, the pilot lamp
will light up continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (See Table 2)
(1) Lamp indication
The indications of the pilot lamp will be as shown in
Table 2, according to the condition of the battery
charger or the battery.
English
Battery
Guide rail
Fig. 7
11