4. INSTALL HOOD MOUNTING BRACKET
! !
VQ0010
When cutting or drilling into wall, do not damage electrical wiring
and other hidden utilities.
Ensure that the wall is solid enough to withstand the weight of the
hood.
If necessary, construct a wall framing using minimum 2" x 4" lumber. Proper
structural support is required to accomodate the weight of the hood.
After the wall surface is finished, measure and mark the center of the
holes on the bracket; draw the vertical center line up to the ceiling.
Carefully center and level the hood mounting bracket over the installation
location. Secure it to the wall framing using 3 no. 8 x 1½" screws.
A
Hood distance above
cooktop (in)
24
25
26
27
28
29
30
Ceiling height
7 ft 7 in to 8 ft 7 in
8 ft 8 in
Standard flue
8 ft 9 in
8 ft 10 in
8 ft 11 in
9 ft 1 in
*Lower part of
optional flue
AEWPP1SBN
9 ft 2 in to 9 ft 6 in
+
Upper part of
standard flue
9 ft 7 in to 11 ft 8 in
11 ft 9 in
11 ft 10 in
Optional flue
11 ft 11 in
AEWPP1SBN
12 ft 1 in
12 ft 2 in
WARNING
B
Mounting bracket holes distance
above cooktop (in)
38-7/8
39-7/8
40-7/8
41-7/8
42-7/8
43-7/8
44-7/8
C
A
Hood distance above
cooktop (in)
24 to 30
25 to 30
26 to 30
27 to 30
28 to 30
9 ft
29 to 30
30
24 to 30
24 to 30
25 to 30
26 to 30
27 to 30
12 ft
28 to 30
29 to 30
30
B
c
ooking surface
HD1530
HD1541
5
A
A
C
36 in