Descargar Imprimir esta página

Broan B5830SS Manual De Instrucciones página 2

Ocultar thumbs Ver también para B5830SS:

Publicidad

Idiomas disponibles

Idiomas disponibles

SR - N
MODELS
B5830SS
• B5836SS
INSTALL
THE DUCTWORK
Page2
(Ducted
Hoods Only)
PREPARE
THE HOOD
1. Decide where
the ductwork
will run
between the
hood and the
outside.
2. A straight, short
duct run will
allow the hood
to perform most
efficiently.
3. Long duct
runs, elbows
and transitions
will reduce the
performance of
ROOF CAP
\
6"
ROUND
DUCT
t
30" TO 36"
ABOVE
COOKING
SURFACE
ROUND
ELBOW
the hood. Use as few of them as possible. Larger ducting
may be required for best performance with longer duct runs.
4. Install wall cap or roof cap. Connect round metal ductwork
to cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.
MEASURE
THE INSTALLATION
ROOF CAP
6" ROUND
ROUND
T
HO_
113/4"
!_
t
30" TO 36" ABOVE
COOKING
SURFACE
WALL CAP
/
HOOD
MOUNTING
BRACKET
t
125/8"
TO CENTER OF
BRACKET HOLES
Unpack hood and check contents. You should receive:
1 - Hood
1 - Decorative Flue Assembly
1 - Damper / Duct Connector
1 - Lower Flue Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Hood Mounting Bracket
2 - Aluminum Grease Filters (installed in hood)
1 - Parts Bag containing:
10 - Mounting Screws (#8 x 3/8" Pan Head)
7 - Mounting Screws (#8 x 1-1/2" Flat Head)
7 - Drywall Anchors
2 - Washers
1 - Installation Manual
I_
10 MOUNTING
SCREWS (#8 x
3/8" Pan Head)
J
DECORATIVEFLUE
DAMPER/DUCT
CONNECTOR
7 MOUNTING
SCREWS
(#8 X 1-1/2"
Flat Head)
FLUEMOUNTING
BRACKET
LOWER
FLUE MOUNTING
BRACKET
2 WASHERS
)
7 DRYWALL
ANCHORS
HOOD
MOUNTING
BRACKET
The minimum
hood distance above cooktop MUST NOT BE
LESS than 30".
A maximum of 36" above cooktop is highly recommended
for
best capture of cooking impurities.
Distances
over 36" are at the installer and users discretion;
providing that the ceiling height permits.

Publicidad

loading

Este manual también es adecuado para:

B5836ss