Installation of appliance
Hold the cooker hood by its body and place it on
the mounting screws on the wall and tighten the
screws (Figure 9).
Install M4 washers to the 5.5x60 suspension
screws. Secure the cooker hood with 5.5x60
screws to the wall through the mounting hole on
the interior of the appliance (Figure 9).
5.4 Connecting to chimney
If you are going to use the Ø 120/150 mm plastic
Chimney adapter, connect one end of the pipe
to this adapter, if you are not going to use it, to
the direct output on the product. Connect the other
end of the pipe to your chimney. Check that these
two connections are tight enough so they will not
come out when the appliance runs on full pow-
er. Check if the flaps inside the chimney operate
when they are tightened with clamps. Connect
the chimney connection duct outside the adapter
(Figure 11/a). If the connection duct is fitted in-
side the adapter, suction of air shall not occur as
the chimney flap that prevents the return of air will
remain closed (Figure 11/b). The length of the
pipe connection as well as the number of elbows
must be as minimum as possible.
A : Chimney exit pipe
B : Non return flaps
C : Plastic flue
The valves are closed then the appliance is not
operating and prevent possible outside odour and
dust from entering inside.
14 / EN
(Figure 10)
(a)
Ok
(Figure 11a/11b)
5.5 Installation of the hood to the
chimney
Make the electrical connection of your hood be-
fore starting the installation of the chimney. Slip
the chimney plates around the body.
Install the chimney plate to the chimney fastening
plate that is secured to the wall from its upper out-
er edges (Figure 12).
Cooker Hood / User Manual
(b)
Not Ok