4. INITIAL CONFIGURATION
backup heater can never be activated during the charging period. Default value: Disabled.
Weekly programming: In this section you can select the charging period and days. Up
to two different periods can be selected by defining the start and end time. The default
settings are: 1 charging period from 00:00 a.m. to 07:00 a.m. every day on the 1700w,
2550w and 3400w models, 1 charging period from 00:00 a.m. to 08:00 a.m. every day on
the 1630w models , 2450w and 3260w.
Balancing: This option allows you to alternate the operation of the resistors every hour
during the charging period, considerably lowering the consumption of the storage. It is
recommended to use this option to charge the storage with energy from the photovoltaic
system. The TWO LOADS and MIXED LOAD options are only available in the 2550w storage.
1700
A load /
850w - 850w
Mixed load
Two loads
-
Switching will always be done every 60 minutes. If the load stops and starts again, it will always do so at the beginning of the cycle.
Smart charge: This option allows you to calculate the excess charge to adjust it in the following days. If
this function is disabled, the storage will charge every day up to the TARGET CHARGE. Default value:
On.
Target load. If the SMART CHARGE parameter is active, this option cannot be modified.
Current charge: Allows the user to see the percentage charge of the storage at that moment.
Units: You can choose between CELSIUS and FAHRENHEIT. Default value: CELSIUS.
Screen: Different aspects can be modified:
Duration: The time in which the screen light is active is defined, 10s, 20s, 30s or always.
Default value: 10s.
Active Brightness: 100%, 75%, 50%, or 25%. Default value: 100%.
Idle Brightness: Off, 3%, 10%, or 20%. Default value: Off.
Style: Light B/W, Dark B/W or Color. Default value: Color.
Speaker: You can choose between disabled or enabled. Default value: disabled.
Control type: It is possible to choose that the product works with a type of control by hysteresis
or by PID. The hysteresis works by the difference between the setpoint temperature and the room
temperature. The PID is based on calculations to achieve the set temperature. Default value: PID15.
Window detection: If this function is active, the storage will stop emitting heat if it detects a
drop in temperature of 1.2ºC in a period of 10 minutes. The storage will show the symbol on the
screen. If any button is pressed or an increase of 0.3ºC is detected in a period of 10 minutes,
the storage will return to its normal state. Default value: Disabled.
: If this function is active, the storage can activate the support resistance or
Smart start
the fan earlier than programmed to reach the desired temperature at the programmed time.
Maximum notice time 12h. Default value: Disabled.
Compensation: The product allows you to set a compensation temperature on the room
temperature sensor. It can be positive or negative. In the edit screen you can see the
compensation value and the corrected room temperature. Default value: 0.0ºC.