5.Cleaning of Laser Module
The laser module and the X-axis dual-axis core need to be regularly cleaned.
After using the laser module for a certain period, some residues may be left on the protective cover, heatsink, and laser head. These
residues should be cleaned in a timely manner to avoid affecting the use of the laser module.
a. The cleaning time is about 8 hours after the laser module is in operation.
b. The windshield and protective cover must be removed before cleaning.
c. It is recommended to use alcohol for cleaning and wiping.
Remove the protective cover, air
guide cover, nozzle, and window
mirror.
6. FAQ
1.Auto focus prompt failure
Solution: Troubleshoot using the following methods:
1)Check if the Z-axis upper and lower limit switches are working properly: Press the upper and lower limit switches separately, and if the display
prompts that it exceeds the maximum range, it is OK.
2) Observe whether the lower limit switch touches the material after the focus is completed. If it does not touch, it is because the Z-axis stroke
has been completed, and the laser's lower limit switch has not come into contact with the tested material. Adjust the Z-axis slider or adjust the
position of the laser. When using roller with the support bracket to engrave longer objects, select the appropriate gear and move the bracket to
the proper position to ensure that the tested object is placed horizontally.
2.Severe burning inside or at the bottom of paulownia or plywood, with no surface ignition and no flame alarm.
Solution: This is a normal phenomenon. The principle of the sensor is to detect surface flames.
Clean with alcohol and a
lint-free cloth.
25
X-axis dual-axis core
alcohol
a lint-free cloth