Descargar Imprimir esta página

ATOMSTACK A6 PRO Manual Del Usuario página 29

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.Flame sensitivity issue
Solution: Troubleshoot using the following methods:
1) Confirm if the pre-focus is within the standard focus range prior to testing.
2) Check if the flame sensor has accumulated dust, if so, clean it to restore sensitivity.
3) Do not use the device in direct sunlight, as sunlight contains strong infrared rays that may cause false triggers.
4) The air pump needs to be turned on for cutting, otherwise it will not be sensitive.
4.The auxiliary positioning function is turned on, but the working area does not meet the claimed value.
Solution: This is a normal phenomenon.
When the auxiliary positioning is turned on, the starting point position is based on the cross laser. The display screen will prompt the following:
A12/A24 Pro Auxiliary Positioning Engraving Range: 356mm*289mm
5.Inaccurate cross positioning
Solution: When replacing the laser, recalibrate using the display screen/APP.
6.Incompatibility with USB drives
Brands commonly found in the market are compatible, such as SanDisk, Kingston, HP, and aigo. If there is a failure to read the USB drive, it is
recommended to format it before use. The USB drive is preferably a FAT32 file system.
7.Display screen prompts "Reset failed"
1) Due to the lack of limit switches for the chuck and rollers, the "Auto-home on startup" and "Resume engraving" functions are not available.
2) Before exporting the GC file using LightBurn, make sure to disable the "Auto-home on startup" function.
8.The energy at the edges of the engraving is deeper.
Solution : Enable overscanning for engraving.
26

Publicidad

loading

Este manual también es adecuado para:

A12 proA24 pro