Descargar Imprimir esta página

Craftsman 139.53906D Manual Del Propietário página 31

Publicidad

Idiomas disponibles

Idiomas disponibles

Using the Wall-Mounted Door Control
Press the push button to open or close the door.
Press again to reversethe door during the
closing cycle or to stop the door while it's
opening.
To Openthe Door Manually
To prevent possible SERIOUSINJURYor DEATHfrom a falling
garage door:
• If possible, use emergency release handle to disengage
trolley ONLYwhen garage door is CLOSED.Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.
• NEVERuse emergency release handle unless garage doorway
is clear of persons and obstructions.
• NEVERuse handle to pull door open or closed. If rope knot
becomes untied, you could fall.
DISCONNECT THE TROLLEY:
The door should be fully closed if
possible. Pull down on the
emergency releasehandle (so that
the trolley releasearm snaps into a
vertical position) and lift the door
manually. The lockout feature
prevents the trolley from
reconnecting automatically, and the
door can be raised and lowered
manually as often as necessary.
Trolley
Trolley --
...J
Release Arm
(In Manual
Disconnect
Position)
Lockout position
(Manual disconnect)
TO RE-CONNECT THE TROLLEY:
Pull the emergency releasehandle
toward the opener at an angle so
that the trolley release arm is
horizontal. The trolley will reconnect
on the next UPor DOWNoperation,
either manually or by using the door
control or remote.
Trolley
0
_ __ml/ey
e
Emergency
"" "%,_
(R1easeanHa B da Ick)_:_,
,,g
To reconnect
31

Publicidad

loading