3.
Remove the oil dipstick with a clean cloth to clean it and insert it into the oil port to check the oil level.
4.
If the oil level is below the maximum dipstick indicator, add the recommended oil.
STARTING AND STOPPING THE ENGINE
CHECK POINTS BEFORE COMMISSIONING
Do not use this machine if it is damaged or incorrectly adjusted. Check the machine:
Look for loose parts (screws, nuts, etc.) and damage.
No fuel leaks.
That the oil and fuel level is correct.
That the air filter is clean. Clean the filter if necessary.
Tighten, repair or replace as necessary before using the machine. Do not use any accessories on this machine other
than those recommended as their use could cause serious injury to the user, the machine, people, animals, and things
near the machine.
ENGINE START
1.
Open the fuel tap by turning it to the "ON" position and open the vent hole in the fuel filler cap.
2.
If necessary, prime the fuel system.
3.
Set the power switch to "ON".
4.
Slowly pull out the recoil starter until you feel it engage with the engine, then pull it out quickly. Hold the
generator handle firmly when pulling the recoil starter to prevent the machine from tipping over. Once
started, allow the starter cable to rewind slowly.
NOTE: Once the engine has started, the engine speed is automatically adjusted according to the
load connected. For example, under high loads, the motor will run at higher speeds to maintain the
required power.
STOPPING THE ENGINE
1.
Turn off and disconnect all electrical devices connected to the generator.
2.
Set the switch to the "STOP" position.
3.
Close the fuel tap to the "OFF" position and close the vent hole in the fuel filler cap.
USE OF CHOKE
In cold conditions or if the normal starting procedure does not work, it may be necessary to open the choke to help
start the engine. Once started, close the strangler.
CONNECTION OF ALTERNATING CURRENT (AC)
Used to power a 240V device that is connected via a standard two-pin plug.
CHECK POINTS BEFORE COMMISSIONING
Make sure all electrical devices, including lines and plug connections, are in good condition before connecting
them to the generator.
Make sure the total load is within the nominal output of the generator.
Make sure that the connected load current is within the rated current of the socket.
Be sure to ground the generator.
CONNECTING THE DEVICES TO THE GENERATOR
1.
Turn on the generator.
2.
Make sure that the device connected to the 240V socket is turned off.
59