Specifications
Laser Beam Function
1 Vertical / 1 Horizontal Cross-Lines
Working Range*
Up to 10m
Laser Beam Color
Green
Laser Type
Emission Wave Length of 510 ~ 530 nm, Class 2, <1 mW
Accuracy*
±8mm @ 9m
Self-Leveling Range
± 4°
Operating Temperature
-10 °C ~ +50 °C
Power Source
3 x AA alkaline or rechargeable batteries
Operating Time
17 hr
a) QuickSet
Mounting Options
b) 6.35mm - 20 thread
Instrument Dimensions
94 x 58 x 86mm
(L x W x H)
Instrument Weight
0,3 kg
(without batteries)
Bracket Clamp Capacity
6mm - 60mm
* Measuring accuracy and working range are dependent on lighting conditions
of the work environment.
®
mount
12
3. HOW TO OPERATE
CAUTION! When moving the instrument from a warm environment into a cool environment,
moisture may accumulate on the Laser Beam Window
to the new environment first. DO NOT turn on a wet or damp instrument.
To wipe the Laser Beam Window
1
DO NOT USE A PAPER TOWEL.
PLEASE NOTE: Laser beam expands as the distance between the instrument and the
target increases. Therefore, always take measurements in the center of the laser line.
Installing the Batteries
Before installing or replacing the batteries, make sure that the Pendulum Switch
is in the LOCK position, and the power is turned OFF.
1. Open the Battery Compartment Cover
2. Insert the batteries observing the polarity. Ensure that the removal band
is positioned under the batteries.
3. Close the Battery Compartment Cover
1
. Allow the instrument to adapt
, use ONLY a lint-free cloth.
7
by pushing the latch
6
and lifting it.
7
until it engages.
13
2