LED Indicator
The red and green indicator
lights flash alternately
The green light is always on
The red light is always on
The green light flashes slowly
Situations
Ready to work
Force starting situation
1. Battery clamp is reversely connected -check whether the
clip is reversely connected.
2. The clamp is short- circuited - check whether two clamps
together connect or connect both cable clamps to the same
piece of metal.
3. The temperature of the clamp exceeds 65(+/-5) degrees -
Remove the clamp until the red and green flash alternatively.
The voltage of the starter is too low, please try to replace the
jump starter or charge it in time
EN