Descargar Imprimir esta página

Würth BLG 12/24V - 50A Traducción Del Manual De Instrucciones De Servicio Original página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
Construction and function
2.1 Overview
Overview of the BLG 12/24 V – 50 A – front
Touch display: Graphical user interface
LED – yellow: Charge mode – main charge
LED – yellow: Charge mode – boost charge
LED – green: Charge mode – end of charge, charge
retention
LED – blue: Support mode
LED – white/red: Battery missing/error
USB interface: Service, programme update
Button: Pause or restart the charger (press
briefly). Switch off the charger (press for more than
3 seconds). Switch on the charger again (press
briefly).
Mains connection: IEC standardised worldwide
socket
Connection for charging cable: (+) red clip,
(–) black clip
2.2 Connection cables
Power cable:
Length: 2 m/fixed
Connection: IEC socket/C13 – Schuko 16 A
Charging cable:
Length: 5 m
Connection: Dinse plug – H300 charging clips
2.3 Device description
The BLG 12/24 V – 50 A battery charger can be
used to charge 12 V or 24 V wet-cell batteries
(lead-antimony, lead-calcium, EFB), maintenance-
free AGM, gel and fleece batteries, and Li-ion
batteries.
The device can also be used as an external power
supply unit (PSU) for motor vehicles.
The BLG 12/24 V – 50 A battery charger has a
desktop housing. An internal fan is used for coo-
ling. Make sure that the ventilation slots of the BLG
12/24 V – 50 A charger are not covered.
Display
The current charging current and current charging
voltage are displayed on the LC touch display
during charging. Light-emitting diodes (LEDs) indi-
cate the current charge status or any fault.
Maximum charging current: at 12/24 V: I
• The battery can remain installed during charging
and does not have to be disconnected from the
electrical system.
• Reliable protection of the vehicle electronics, as
no current or voltage peaks occur.
External PSU operation
(external power supply)
The charger works in support mode as an external
power source. This allows electrical systems in
vehicles to be powered and tested even without a
battery.
Buffer operation
The charger ensures safe charging and retention of
the battery charge in charge mode, even when the
consumer is switched on: up to 60 A at 24 V and
50 A at 12 V.
Reverse polarity protection
The charger detects any reversed polarity and
does not start the charging process when in charge
mode. The white LED will light up.
= 50 A
N
21

Publicidad

loading

Este manual también es adecuado para:

0510 955 8500510 955 851