Installation Instructions
INSTALLATION - RECIRCULATING
[3
MOUNTING
HOOD TO BOTTOM OF
CABINET (Continued)
e Lift the hood to the installation position. Locate
the house wiring and route it through the knock-
outs at the top right of the hood. Lift the hood
and engage the key hole slots over the mounting
screws and slide it back against the wall. Tighten
the mounting screws. Add 2 additional screws at
the front and center the hood on the riser.
e Install 4 wall screws into the anchors or studs to
complete the hood mounting.
Mounting screw
Key hole slot
in hood
Additional
a
screws to riser
Wall screws
and washers for
anchors or studs
[ 4 |JCONNECTING ELECTRICAL
Verify that the power is turned off at the source.
A WARNING:
if the house wiring is not
2-wire with a ground wire, a ground must be pro-
vided by the installer. When house wiring is alu-
minum, be sure to use UL-approved antioxidant
compound and aluminum-to-copper connectors.
e Remove the junction box cover.
e Secure the house wiring to the junction box with a
strain relief (not provided).
¢ Connect the white lead to the branch circuit white
lead.
17
[ 4 CONNECTING ELECTRICAL (Continued)
¢ Connect the black lead to the branch circuit black
lead.
* Connect the green/yellow lead to the branch cir-
cuit green lead or bare ground lead.
e Secure all the connections with wire nuts on each
electrical connector. Check for secure wiring con-
nections.
e Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
e Secure the junction box cover with the 2 original
Screws.
Put the main power disconnect switch located on the
control box cover to the ON position. Test all hood
functions to ensure electrical connections. See the
owner's manual for instructions to test operations.
Strain relief
House
Junction box
wiring
cover
i
Black
UL listed
leads
wire nuts
White
leads
Green/yellow
ground wires