3.Unable to reach "FUL" status after charging in long time.
The battery has been vulcanized, or feeder, or water depletion in the battery. The
battery voltage will keep low status, causing the battery unable to get fully charged.
Solutions: Stop to charge when the battery is heating, check the battery is in
shortage of liquid or Not. please charge cycle 1-2 times (Discharge-Charge,
Discharge-Charge).
4. Why can't choose repair mode?
The battery and AC power are not connected to the charger.
Specifications
Model
Input Voltage
Input Current
Charge Voltage
Input Power under No Load
Output Voltage
Bulk Charge Current
Operate Temperature
Cooling
Battery Type
Battery Capacity
Size
Net. Weight
Approval
The table shows the up to about 100% state of charge
Battery Capacity(Ah)
20
60
80
120
all type of 12V AGM, GEL, Flooded(Wet), Calcium,
4
FBC1207E
100-240VAC 50/60Hz 90W
0.4A@230VAC, 0.8A@110VAC
Car mode: 14.8V, AGM mode: 14.6V,
Motorcycle mode: 14.6V
(Measurements allowed tolerance +/-0.3V)
Max. 7A
-20℃ to +45℃
deep cycle, VRLA, maintenance free, lead
acid ,LiFePo4 batteries
4Ah - 140AH
158*85*63mm
CE / FCC / RoHS
2.5W
12V
Fan
440g
Time(hours)
1
3
10
15
20
English
5