3. Remove the bolts and parking brake panels.
 
 
4. Examine the parts of the control levers for
damage.
5. Examine the parking brake assemblies to make
sure that no parts are missing.
6. Replace all damaged or missing parts.
7. Push the control levers fully away from the seat.
8. Measure the clearance (A) between the interlock
bracket and the adapter with a feeler gauge.
The correct clearance is 0.030–0.060 in./0.75–
1.5 mm.
 
C
B
 
9. Loosen the locknut (C) with a 1/2-in. wrench.
10. Set the correct clearance between the interlock
bracket and adapter.
a) Loosen or tighten the adjustment nut (B).
b) Measure the clearance.
c) Hold the adjustment nut (B) in the correct
position and tighten the locknut (C).
11. Engage and disengage the parking brakes a
minimum of 6 times to make sure that they
operate correctly. Refer to
disengage the parking brake on page 12 .
12. Measure the clearance (A) between the interlock
bracket and adapter again.
2312 - 001 - 29.11.2023
A
To engage and
13. Make sure that there is no tension in the parking
brake cables when the control levers are pulled
fully in the direction of the seat. Do not add
tension to the parking brake cables.
14. Install the parking brake panels and tighten the
bolts.
To charge the battery
Charge the battery if it is too weak to start the
Battery charging times on page
engine. Refer to
30 for battery charging times.
Use a standard battery charger.
CAUTION:
charger or start booster. A boost
charger or a start booster will cause
damage to the electrical system of
the product.
Always disconnect the battery charger before
you start the engine.
To do an emergency start of the
engine
If the battery is too weak to start the engine, you can
use jumper cables to do an emergency start. This
product has a 12 V system with negative ground.
The product that is used for the emergency start
must also have a 12 V system with negative ground.
To connect the jumper cables
WARNING:
because of explosive gas that comes
from the battery. Do not connect the
negative terminal of the fully charged
battery to or near the negative terminal
of the weak battery.
CAUTION:
the product to start other vehicles.
1. Connect one end of the red cable to the
POSITIVE battery terminal (+) on the weak
battery (A).
B
A
Do not use a boost
Risk of explosion
Do not use the battery of
C
D
19