RECORD
STEADYPRES does not require any type of routine maintenance if used within the use limitations and in compliance with the
instructions outlined in this manual.
Only authorised service centres may carry out reactive maintenance or repairs.
Use only original spare parts for repairs. The manufacturer cannot be held in any way liable for damage to people, animals or
property due to maintenance interventions carried out by unauthorised staff or using non-original materials.
INSTALLING THE EXPANSION BOARD (optional)
2
Disconnect voltage to the inverter and wait 2 minutes to
discharge the capacitors.
• Remove the front cover to access the board compartment.
• Install the board (1) in position, correctly connecting the connector
(2) in its compartment.
• Tighten the three fastening screws (3).
• Re-assemble the front cover correctly.
REPLACING THE FUSES
2
Disconnect voltage to the inverter and wait 2 min-
utes to discharge the capacitors.
• Remove the front over.
• Unscrew and remove the three screws (1).
• Unscrew and remove the four spacers (2).
• Disconnect the connectors (3) and (4).
• If present, remove the expansion board (5).
• Remove the internal cover (6).
• Replace the fuse (7) with one the same capacity (16 A).
• Re-assemble everything correctly following the operations in
reverse order.
34 | ENGLISH
1
2
3
4
5
6
3
7
1
2