IMPORTANT! KEEP THESE INSTRUCTIONS FOR
EN
FUTURE REFERENCE.
WARNINGS FOR USING LITHIUM POLYMER BATTERIES:
• ONLY an adult can plug the adaptor!
• Do not bend, drill (especially with metal objects) or damage the battery in any other way.
• Charge the battery only with the adaptor provided by the producer!
• Do not allow short circuit!
• Keep the product in room temperature!
• Do not subject to direct sunlight!
• Never leave a charging battery without supervision!
Battery may explode if mistreated!
REMARK: The battery compartment is located inside the main device.
ADVICE: Charge the battery fully before use to save it and prolong its life.
IMPORTANT! To replace the battery contact the retailer or an authorized service!
CAUTION! When you stop using the product, do not dispose of it with normal house- hold waste but hand it over in an official waste collecting point. The waste formed from damaged electrical and video devices, batteries,
adaptors, must be disposed of separately. Throwing them out in containers for household waste is forbidden.
PARTS (Figure I):
1. Dust cap; 2. Silicone shield; 3. Main unit; 4. Diaphragm, 5. Silicone stopper; 6. USB charging cable and adaptor; 7. Valve; 8. Milk collector cup; 9. Silicone insert 19mm (for 19-21mm); 10. Silicone insert 22mm (for
22-24mm); 11. Bra adjustment buckle; 12. Travel pouch.
DISPLAY (Figure II):
1. Suction decrease; 2. Power/Pause button; 3. Suction level; 4. Massage mode; 5. Battery indicator; 6. Suction increase; 7. Mode change button; 8. Pumping mode; 9. Bionic mode; 10. Session duration.
• Power/Pause button: press for 2 seconds to switch on or off the breast pump. Tap once to pause the pumping when needed.
• Mode change button: touch once to change the mode, do not touch for too long.
• When the breast pump is switched on, it will start with the Massage mode. After 2 minutes of use, it will automatically change to Pumping mode.
• Digital display features memory and timer for easy tracking and recording pumping sessions. When switched on, the pump's memory will automatically use the suction settings from the previous pumping session.
• Suction levels: Massage mode: L1-L9; Pumping mode: L1-L9; Bionic mode: L1-L9.
• Battery indicator: it shows the rest battery percent, please charge when the battery is low.
• Session duration: indicates the length of your pumping session. The pump will automatically switch off after 30 minutes use.
INSTRUCTION FOR USE:
Cleaning and sanitizing (Figure III):
The main device, the USB cable and the adaptor do not require cleaning and sanitizing, as they do not come into contact with breast milk. Clean and sanitize all other parts of the breast pump before first use.
• Clean these parts after each subsequent use and disinfect them before each subsequent use.
Caution! Never put the main device, USB cable or the adaptor in water, in a dishwasher or in a sanitizer, as this causes permanent damage to these parts.
• Disassemble the breast pump completely. Also, remove the valve. Be careful when removing the valve and cleaning it. If it breaks, your breast pump will not work properly.
• To clean the valve, gently rub it between your fingers in warm water with a little liquid detergent. Do not insert objects into the valve as this may damage it.
• Before first use, disinfect in boiling water for 5 minutes all parts except the main device, USB cable and the adaptor. This ensures hygiene.
• During the disinfection with boiling water, do not allow the parts to touch the side of the pot. This may cause irreparable deformation or damage to the product for which KikkaBoo is not responsible.
• Clean carefully before each subsequent use to ensure hygiene.
• Wash all parts, except the main device, USB cable and the adaptor with warm water and delicate detergent.
• Always rinse all parts except the main device, USB cable and the adaptor thoroughly after each wash.
• Wash thoroughly and rinse all parts, except the main device, USB cable and the adaptor with clean water, including areas that may not be visible but through which the milk has passed, to remove milk debris.
• All parts, except the main device, USB cable and the adaptor can be sterilized up to 10 minutes in a steam sterilizer intended for nursing mothers and baby products.
• Do not place in a dishwasher.
• Do not place in a microwave oven. Do not heat the product in traditional ovens, on hot plates or open flames.
• Avoid the use of sharp or abrasive materials, as this may damage the product.
• Do not clean or allow the product to come into contact with solvents or aggressive chemicals. This may damage the product.
• After cleaning the product, dry all parts thoroughly and store in a clean and dry place without direct sunlight and away from heat sources.
Note: Be sure to clean and disinfect the relevant parts of the breast pump. Wash your hands thoroughly before working on clean parts!
Warning! Be careful, as the cleaned parts may still be hot. Only start assembling the breast pump when the cleaned parts are cooled down.
Note: It is normal if there is a residual smell. Clean the product according to the instructions, it can help effectively reduce or eliminate the smell.
When to wash and sanitize (Figure III):
• Before first use wash and sanitize: the breast shield and inserts (I-2; I-9; I-10); breast pump kit (I-4; I-5; I-7) and milk collector cup (I-8).
• After each use wash: the breast shield and inserts (I-2; I-9; I-10); breast pump kit (I-4; I-5; I-7) and milk collector cup (I-8).
• Once per day sanitize: the breast shield and inserts (I-2; I-9; I-10); breast pump kit (I-4; I-5; I-7) and milk collector cup (I-8).
Dry all parts after washing or sanitizing. Wash your hands and assemble the complete breast pump according to the figure IV.
BATTERY OPERATION:
WARNING! Before first use, fully charge the battery for 2 hours uninterrupted! Once the pump is turned on, the battery indicator icon on the display will show the remaining battery life until the battery runs out.
When the battery is low the battery indicator icon will start flashing. When the battery is fully charged the indicator will display a full battery icon. Attention: Battery cannot be charged over 24 hours.