Descargar Imprimir esta página

GreenWorks Pro ULTRAPOWER 60V CS60L810 Manual Del Operador página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Problem
The machine
does not start.
The motor runs,
but the chain
does not cut cor-
rectly, or the mo-
tor stops after
around 3 sec-
onds.
Possible cause
Solution
Pull the chain
brake in the di-
The chain brake
rection of the
is engaged.
user to disen-
gage it.
Make sure that
The machine
the battery re-
and battery are
lease button
not connected
clicks when you
correctly.
install the battery
pack.
The battery level
Charge the bat-
is low.
tery pack.
1. Push the
lock-out but-
The lock out but-
ton and hold
ton and the trig-
it.
ger are not push-
ed at the same
2. Push the trig-
time.
ger to start
the machine.
The battery is
Refer to battery
too hot or too
and charger
cold.
manual.
Release the trig-
The machine is
ger and start the
in the protection
machine again.
mode to protect
Do not force the
the PCB.
machine to cut.
Charge the bat-
tery. Refer to the
The battery is
battery and
not charged.
charger manual
for correct charg-
ing procedures.
Lubricate the
chain to de-
crease the fric-
The chain is not
tion. Do not let
lubricated.
the guide bar
and the chain
operate without
sufficient oil.
Cool the battery
Incorrect battery
pack until it de-
storage tempera-
creases to the
ture
ambient temper-
ature.
English
Problem
The machine
has stopped
working to pro-
tect internal cir-
cuits.
13
TECHNICAL DATA
Voltage
No load speed
Guide bar length
Chain pitch
Chain gauge
Drive links
Chain oil capacity
Weight (without battery
pack)
Chain
Guide bar
Battery model
Charger model
The recommended ambient temperature range:
Item
Appliance storage temper-
ature range
Appliance operation tem-
perature range
Battery charging tempera-
ture range
Charger operation temper-
ature range
Battery storage tempera-
ture range
Battery discharging tem-
perature range
16
Possible cause
Solution
Operating tem-
Move the ma-
perature of the
chine to a cool,
machine is too
dry location. Let
high.
rest for 5-10 mi-
nutes at least. If
the protection is
frequent, extend
the cooling time.
60 V DC
25 m/s
20'' (508 mm)
0.325" (8.25 mm)
.050" (1.27 mm)
78
250 ml
12.4 lbs. (5.6 kg)
20LPX078X/95TXL078X
200PXBK041/200MLBK0
41
60BA08 and other BAC
series
CAC801/CH60R00/
CH60DP01/60DPC10A
and other CAC series
Temperature
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 113°F (45°C)
39°F (4°C) - 104°F (40°C)
39°F (4°C) - 104°F (40°C)
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 113°F (45°C)

Publicidad