WARNINGS:
• TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
Product Description
The Weather Resistant Single Pole Switch is a self-contained switch for use in a standard,
single-gang, FS or FD weatherproof box.
NOTES:
• Install this switch over smooth, flat surfaces (metal or vinyl siding, clapboard, or plywood).
If the mounting surface is not smooth, use silicone sealant to ensure a proper seal.
• Mount the device in a in single-gang wallbox only.
• Only use the six provided mounting screws.
• For use in a standard single-gang wallbox, mount the device in the two center screw
locations and with two of the provided screws. Tighten the screws with 14-16 in.-lb of torque.
• For use in an FS or FD weatherproof box, mount the device in the two center screw
locations and the additional four screw locations with the six provided screws. Tighten the
screws with 14-16 in.-lb of torque.
• Use a punch or 9/64 in. drill bit to
remove extra material in additional
four screw mount locations.
Installation
1.
Remove wallplate.
Insert a flat-head screwdriver into the notch at the bottom of the
wallplate to remove it.
2.
Identify your wires (most common):
LOAD
LINE
From Branch Circuit
3.
Wire.
Work on one connection at a time, and connect wires, as shown below.
To Back Wire: Remove
insulation per strip gauge on
device approximately
5/8 in. (1.6 cm). Insert
straight wires under clamps
of appropriate terminal
screws. Tighten with
14-18 in.-lb of torque.
NOTES:
• For 15A devices: Back wire terminals accept
#10-14 AWG copper or #10-12 AWG
copper-clad wire.
• For 20A devices: Back wire terminals accept
#10-12 AWG copper or #10 AWG
copper-clad wire.
Weather Resistant Single Pole Switch
Cat No. W5601 Rated:15A-120/277V AC
Cat No. W5621 Rated: 20A-120/277V AC
INSTALLATION INSTRUCTIONS
To Load
NEUTRAL
GROUND
To Load
NEUTRAL
LOAD
GROUND
LINE
From Branch Circuit
To Side Wire: Remove
insulation approximately
5/8 in. (1.6 cm) per strip
gauge on device.
Loop wires clockwise 3/4
around terminal screws.
Tighten with 14-18 in.-lb
of torque.
NOTES:
• For 15A devices: Side wire terminals
accept #12-14 AWG copper or #12 AWG
copper-clad wire.
• For 20A devices: Side wire terminals
accept #12 AWG copper wire only.
CAUTIONS:
• To avoid damage to the product, DO NOT use disinfecting products, including foggers,
sprays or other types of atomized cleaning agents.
• DO NOT spray liquid onto the product.
• To clean, use a damp cloth with mild soap.
• Use this device WITH COPPER OR COPPER-CLAD WIRE ONLY.
4.
Mount.
5.
Tighten mounting screws.
Tighten screws with 14-16 in.-lb of torque to ensure a proper seal.
Seal between gasket
and mounting surface.
6.
Install wallplate.
Make sure the notch is on the bottom of the wallplate.
7.
Restore power.
Restore power at circuit breaker or fuse. Installation is complete.
Patents covering this product, if any, can be found on www.leviton.com/patents.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at
Leviton Manufacturing of Canada ULC to the attention of the Quality Assurance Department,
165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product
at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair
or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty
is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance
with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the
applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness
for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
DI-000-W56X1-20A-X3
ENGLISH
or
Seal between all mounting
screws and individual
mounting screw gaskets.

Publicidad

loading

Resumen de contenidos para Leviton W5621

  • Página 1 Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair...
  • Página 2 Serrer les vis en appliquant un couple de 14-16 po-lb (1,6-1,8 N-m) pour assurer l’étanchéité du dispositif. Leviton garantiza al consumidor original de sus productos y no para beneficio de nadie más que este producto en el momento de su venta por Étanchéiser les espaces entre le joint et la surface de fixation.