SPECIFICATIONS
The specifi cations of this machine are listed in the Table on
page 217.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
Before
charging
While
charging
Charging
Pilot lamp
complete
(red)
Charging
impossible
Overheat
standby
● Regarding the temperatures and charging time of the battery.
The temperatures and charging time will become as shown in Table 2.
Type of battery
Temperatures at which the
battery can be recharged
Charging voltage
Battery
Charging time,
approx. (At 20°C)
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for
Flickers
0.1 seconds. (off for 0.1 seconds)
Lights for 1 second. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
Charger
V
14.4
BSL14xx series
(4 cells)
BSL1415S : 20
BSL1415 : 22
BSL1415X : 22
min.
BSL1420 : 30
BSL1425 : 35
BSL1430C : 45
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to the receptacle.
When connecting the plug of the charger to a receptacle,
the pilot lamp will blink in red (At 1- second intervals).
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 3 (on page 2).
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot lamp
will blink in red. (At 1-second intervals) (See Table 1)
● Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Table 1
Table 2
UC18YFSL
Li-ion
0°C–50°C
BSL18xx series
(8 cells)
(5 cells)
BSL1815S : 20
BSL1815 : 22
BSL1430 : 45
BSL1815X : 22
BSL1440 : 60
BSL1820 : 30
BSL1450 : 75
BSL1825 : 35
BSL1460 : 90
BSL1830C : 45
BSL1850C : 75
10
Malfunction in the battery or
the charger
Battery overheated. Unable
to charge. (Charging will
commence when battery cools)
18
Multi volt
series
(10 cells)
(10 cells)
BSL1830 : 45
BSL1840 : 60
BSL36A18 : 75
BSL1850 : 75
BSL36B18 : 120
BSL1860 : 90