1
General safety precautions
Warning: incorrect installation may cause severe
damage or injury. Read the instructions carefully
before installing the product.
This installation manual is intended for qualified
personnel only. ROGER TECHNOLOGY cannot be held
responsible for any damage or injury due to improper
use or any use other the intended usage indicated in this
manual.
Installation, electrical connections and adjustments
must be performed by qualified personnel, in accordance
with best practices and in compliance with applicable
regulations.
Before installing the product, make sure it is in perfect
condition.
Disconnect the mains electrical power before performing
any work. Only use original spare parts when repairing or
replacing products.
The packaging materials (plastic, polystyrene, etc.)
should not be discarded in the environment or left within
reach of children, as they are a potential source of danger.
2
Symbols
The symbols and their meaning in the manual or on the
product label are indicated below.
Generic danger
Important safety information. Indicates
operations and situations in which the
personnel involved must pay close attention.
Refer to the Installation and use instructions
Indicates the obligation to refer to the manual
or original document, which must be available
for future use and must not be damaged in any
way.
Indicates the admissible temperature range.
Direct current (DC)
Symbol for the product disposal according to
the WEEE directive
3
Product description
The B71/BCHP battery charger board may be used
to charge two 12V
connected in series.
In the event of mains power loss, the battery charger
provides auxiliary power to the control unit (CTRL,
CTRL/P, EDGE1 or B70/1DCHP).
The battery kit, complete with the battery charger board,
wiring and two 12V , 4500 mAh batteries, available for
the BIONIK batteries is BI/BAT/KIT.
Two battery kits are available, complete with battery
charger board and two 12V
box, available is B71/BCHP/EXT.
4
Technical characteristics
MAINS POWER VOLTAGE
MAXIMUM POWER
ABSORPTION
10 10
4500 mAh lead acid batteries
4500 mAh batteries and
36V
15 W
LEAD ACID BATTERIES
FUSES
NOMINAL CHARGING
VOLTAGE
MINIMUM BATTERY VOLTAGE
FOR SELF-PROTECTION
CHARGE CURRENT
OPERATING TEMPERATURE
DEGREE OF PROTECTION
DIMENSIONS B71/BCHP
DIMENSIONS HT418
5
Electrical connections for BI/BAT/KIT
(fig. 2)
With the unit disconnected from mains power:
• Remove the barrier (1) head. Lift the fairlead (2) and
remove the connector (3).
• Lift the central cover and the control unit (4).
• Insert the batteries inside their housing (5)
• Remove the Faston connector from the positive (+)
battery terminal.
• Connect the batteries to the control unit:
• Connect the red cable to the BATTERY (+) terminal of
the control unit.
• Connect the black cable to the BATTERY (-) terminal
of the control unit.
• Reconnect the Faston connector to the battery
terminal (+) of the battery.
• Insert the battery charger in the BATTERY CHARGER
(6) connector of the control unit.
For further information see the manual of the
control unit (CTRL o CTRL/P)
6
Electrical connections for B71/BCHP/
EXT (fig. 3-4-5)
With the unit disconnected from mains power:
• Remove the Faston connector from the positive (+)
battery terminal.
• Connect the battery charger to the BATTERY
CHARGER connector of the control unit.
• Fasten the battery kit (B71/BCHP/EXT) wall-mounted
at a distance of no more than 3 m from the control
unit, or install it inside the barrier, and connect the
batteries to the control unit with a 1.5 mm 2 core cable
not longer than 3 m.
• Connect the red wire to the BATTERY (+) terminal
of the control unit and to fuse F3 integrated in the
housing (detail A). This connects the positive terminal
to circuit in serial with the fuse.
• Connect the black wire to the BATTERY (-) terminal of
the control unit and to the terminal block adjoining the
fuse F3.
• Reconnect the Faston connector to the battery
terminal (+) of the battery.
For further information see the manual of the
control unit (CTRL - CTRL/P - EDGE1 - B70/1DCHP)
2x12V
4500 mAh
F1= F2A (5x20 rapid)
power circuit protection
F2= F10A (5x20 rapid)
battery charger output
protection
F3= T10A (5x20 delayed)
battery protection (detail A)
27,6V
19,5V
400 mA
-20°C
+55°C
IP00
83x52x18 Weight 38g
320x230x120 Weight 4,8kg