The instrument satisfies the requirements for electromagnetic compatibi-
lity. Please note that under the influence of unfavourable field strengths,
e.g. during the operation of wireless telephones or radiological instru-
ments, adverse effects on function cannot be excluded.
Attention!
There is a possible danger of inflammation of gases, if the instrument is
operated in the presence of inflammatory mixtures or mixtures of phar-
maceuticals and air or oxygen or laughing gas!
Never attempt to take the instrument apart!
There is a danger of life-threatening electrical shock.
Unplug the instrument before cleaning or when disinfecting.
3. Intended use
The wall instrument ri-former
manufactured for use with various instrument heads and modular com-
ponents for non-invasive diagnostics.
4. Attachment
a.) Drilling instructions/drilling plan
The drilling instructions and the drilling plan are enclosed separately.
Follow the drilling instructions in order to drill the holes in the wall.
b.) Attaching the wall mounting plates
After you have drilled the holes, take the plugs supplied and push them
into the holes as far they will go.
Take the wall mounting plate and hold it onto the wall so that the screws
can be pushed through the holes of the mounting plate into the plugs.
Now screw in the screws with a screw driver, as far as they will go.
c.) Attachment of the diagnostic station
When all screws have been screwed in tightly, take the diagnostic stati-
on and guide the screw heads through the openings (1). Then press the
diagnostic station downwards until it snaps into place.
d.) Attachment of the extension module
Connect the diagnostic station and the extension module with the help of
the connecting cable.
In order to plug in the connecting cable, remove the sliding cover (2) of
the diagnostic station.
Close the casing opening of the extension module, which is not needed,
with the sliding cover (2).
Take the extension module and guide the screw heads through the ope-
nings (1). Then press the extension module downwards.
Attention:
Take care that the connecting cable does not get caught behind the
extension module.
Push the connecting cable into the groove provided on the reverse side
of the extension module.
5. Operation and function
Putting the diagnostic station into service
with or without extension module:
Put the plug into the electrical socket. The optional clock starts to blink.
You can adjust it to local time by repeatedly pressing the keys; with the