Descargar Imprimir esta página

IKEA MITTZON Manual Del Usuario página 6

Ocultar thumbs Ver también para MITTZON:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
Troubleshooting MITTZON
Symptom
The table does not move.
Orange light blinks.
Only one leg is moving. Orange
light blinks.
The table stops and reverses
during operation.
The table has stopped working.
Burning smell from short-circuit/
motor/power supply/control units.
Abnormal noise from table leg.
One segment of the 3-segment
leg does not move.
Overheat protection status.
Check
1. Make sure that all cables are undamaged and connected firmly in
place.
2. Unplug the desk from the wall socket for approximately one minute
and reconnect.
1. Make sure that all cables are undamaged and connected firmly in
place.
2. Unplug the desk from the wall socket for approximately one minute
and reconnect.
1. Make sure that the table is not overloaded. (Max load 80 kg/176 lbs)
2. Make sure that nothing is blocking the table.
3. Check that the electrical cable has full movement when the desk is
in its highest position and has reasonable slack
Unplug the desk from the wall.
Check that the sound is normal or abnormal when you move the
desktop up and down.
/
/
Try
1. Reconnect all the cables.
2. Follow the instructions to perform a reset. If the problem remains,
contact IKEA customer service.
1. Reconnect all the cables.
2. Follow the instructions to perform a reset. If the problem remains,
contact IKEA customer service.
Remove the heavy things from the desk.
Remove the obstacle. Follow the instructions to perform a reset.
If the electrical cable is trapped, release it. Make sure it has enough
length when the desk is in its highest position.
Identify the burned parts, then contact IKEA customer service.
Follow the instructions to perform a reset. If problem remains, identify
the defective parts and contact IKEA customer service.
Follow the instructions to perform a reset. If problem remains, identify
the defective leg and contact IKEA customer service.
This is not an error status, but due to the motor working continuously,
overheat protection may activate. After approx. 18 minutes of rest, the
blue light will turn off and normal operation can be resumed.